Procedure for Manual Control Pre-Set
1- Adjust controller for closed-loop operation and obtain
good molded parts. This will adjust the controller to the
proper temperature.
2- Position the module select switch to open-loop and set
the manual control knob to roughly 25%. Wait for 10
seconds, than momentarily switch to closed-loop mode
to examine the temperature. If it is above the setpoint,
the manual power is too high to maintain proper
temperature. If it is below setpoint, the manual power
is too low. Adjust the power control knob accordingly,
wait for 10 seconds, then re-examine the temperature
by switching momentarily to closed-loop mode. Repeat
this procedure until the temperature is the same in
either automatic or manual control.
E.Standby Heat (SAM module only)
Standby heat is a low heat level used to keep heaters and
associated equipment warm. Its purpose is to prevent moisture
build-up in heaters and equipment during idle periods and to
provide fast start-up when returning to normal operations.
When using a Standby Alarm Module (SAM), activate the standby
switch. The SAM will send a standby command to all controllers.
A controller, upon receiving the command, will respond accord-
ingly to its present mode of operation:
a- If the controller is in closed-loop mode, the set-
point becomes 200 degrees F (93°C) regardless of
the setpoint switch setting. The Remote Standby
Indicator (the decimal of the last digit) will be
10