The IMP plug-in controller is capable of receiving a standby
command from the SAM auxiliary module. When a standby or low
heat command is acknowledged from the SAM during closed-
loop operation, the controller will operate with a fixed setpoint.
When receiving a standby command during open-loop operation,
the output power of the controller will be reduced to 1/4 of the
front panel power control setting.
The IMP controller also sends alarm status conditions to
the SAM auxiliary module for annunciation and remote
control functions.
Section II. Installation (IMP Series Only)
All IMP Series controllers are ready to use as shipped from the
factory. Prior to installation into a mainframe, make sure the
voltage, Hz and degree options are as ordered and correspond to
the Product ID label.
CAUTION
Never insert or remove a controller from a mainframe
with the AC power on. Hazardous potentials exist on
components inside the mainframe and controller.
Always disconnect AC power to the mainframe when
servicing.